getInstallerDeviceVirtualChassis
Return Virtual Chassis status for an installer-managed switch, including topology and member statistics.
The response is a combined view of the Virtual Chassis state.
Preferred authentication method for automation and integrations. Send the API token in the HTTP Authorization header.
Format:
Authorization: Token {apitoken}
Notes:
- An API token generated for a specific admin has the same privileges as that admin
- An API token is automatically removed if it is not used for more than 90 days
- SSO admins cannot generate admin API tokens. Use organization API tokens when scoped Org/Site privileges are needed.
In: header
Path Parameters
uuidFPC0 MAC address
Response Body
curl -X GET "https://example.com/api/v1/installer/orgs/000000ab-00ab-00ab-00ab-0000000000ab/devices/aff827549235/vc"{ "config_type": "nonprovisioned", "id": "00000000-0000-0000-1000-52d9107af289", "mac": "52d9107af289", "members": [ { "boot_partition": "junos", "cpld_version": "6", "cpu_stat": { "idle": 69, "interrupt": 1, "load_avg": [ 0.8, 1.09, 1.07 ], "system": 11, "user": 19 }, "fans": [ { "airflow": "out", "name": "Fan Tray 0 Fan 0", "rpm": 0, "status": "ok" }, { "airflow": "out", "name": "Fan Tray 1 Fan 0", "rpm": 0, "status": "ok" } ], "fpc_idx": 0, "mac": "52d9107af289", "memory_stat": { "usage": 42 }, "model": "EX2300-48P", "pics": [ { "index": 0, "model_number": "EX2300-48P", "port_groups": [ { "count": 48, "type": "GE" } ] }, { "index": 1, "model_number": "EX2300-48P", "port_groups": [ { "count": 4, "type": "SFP/SFP+" } ] } ], "poe": { "max_power": 750, "power_draw": 40.4, "status": "AT_MODE" }, "poe_version": "2.1.1.19.3 (type1)", "psus": [ { "name": "Power Supply 0", "status": "ok" } ], "recovery_version": "21.4R3-S4.18", "serial": "JW0000000000", "temperatures": [ { "celsius": 33, "name": "CPU Sensor", "status": "ok" }, { "celsius": 29, "name": "PSU Sensor", "status": "ok" } ], "type": "fpc", "uboot_version": "U-Boot 2016.01-rc1 (Nov 11 2016 - 14:26:00 -0800) 1.3.2", "uptime": 27636720, "vc_links": [ { "neighbor_module_idx": 1, "neighbor_port_id": "vcp-1/1/0", "port_id": "vcp-0/1/0" } ], "vc_mode": "HiGiG", "vc_role": "master", "vc_state": "present", "version": "21.4R3-S4.18" }, { "boot_partition": "junos", "cpld_version": "6", "cpu_stat": { "idle": 76, "interrupt": 0, "load_avg": [ 0.96, 0.87, 0.76 ], "system": 6, "user": 17 }, "fans": [ { "airflow": "out", "name": "Fan Tray 0 Fan 0", "rpm": 0, "status": "ok" }, { "airflow": "out", "name": "Fan Tray 1 Fan 0", "rpm": 0, "status": "ok" } ], "fpc_idx": 1, "mac": "d0dd4991652d", "memory_stat": { "usage": 18 }, "model": "EX2300-48P", "pics": [ { "index": 0, "model_number": "EX2300-48P", "port_groups": [ { "count": 48, "type": "GE" } ] }, { "index": 1, "model_number": "EX2300-48P", "port_groups": [ { "count": 4, "type": "SFP/SFP+" } ] } ], "poe": { "max_power": 750, "power_draw": 21.2, "status": "AT_MODE" }, "poe_version": "2.1.1.19.3 (type1)", "psus": [ { "name": "Power Supply 0", "status": "ok" } ], "recovery_version": "21.4R3-S4.18", "serial": "JW3619300922", "temperatures": [ { "celsius": 32, "name": "CPU Sensor", "status": "ok" }, { "celsius": 29, "name": "PSU Sensor", "status": "ok" } ], "type": "fpc", "uboot_version": "U-Boot 2016.01-rc1 (Nov 11 2016 - 14:26:00 -0800) 1.3.2", "uptime": 27636720, "vc_links": [ { "neighbor_module_idx": 0, "neighbor_port_id": "vcp-0/1/0", "port_id": "vcp-1/1/0" } ], "vc_mode": "HiGiG", "vc_role": "backup", "vc_state": "present", "version": "21.4R3-S4.18" } ], "model": "EX2300-48P", "num_routing_engines": 1, "org_id": "1e9a61a9-bc42-42ca-bf67-1ad87443d9b8", "serial": "JW3619300157", "site_id": "ab0aca7a-d45c-469b-b3bb-4fe240642d0b", "status": "connected", "type": "switch", "vc_mac": "52d9107af289"}updateInstallerMap PUT
Modify map or floorplan metadata for an installer-managed site, including dimensions, orientation, and placement-related settings.
createInstallerVirtualChassis POST
For models (e.g. EX3400 and up) having dedicated VC ports, it is easier to form a VC by just connecting cables with the dedicated VC ports. Cloud will detect the new VC and update the inventory. In case that the user would like to choose the dedicated switch as a VC master or for EX2300-C-12P and EX2300-C-12T which doesn't have dedicated VC ports, below are procedures to automate the VC creation: 1. Power on the switch that is chosen as the VC master first. And then powering on the other member switches. 2. Claim or adopt all these switches under the same organization’s Inventory 3. Assign these switches into the same Site 4. Invoke vc command on the switch chosen to be the VC master. For EX2300-C-12P, VC ports will be created automatically. 5. Connect the cables to the VC ports for these switches 6. Wait for the VC to be formed. The Org’s inventory will be updated for the new VC.